Volumendurchflussmesser IR-OPFLOW aus PVDF

Technical specifications

  • Accuracy:
    IR-Opfiow 10 series: ± 1% of measured value
    IR-Opflow 30 series: ± 3% of measured value
  • Repeatability:± 0, 1 % of measured value.
  • Calibrated linearity: ± 1% or ± 3%
    of measured value (depending on
    selected calibration series).
  • Measurement range:   See table 1.
  • Temperature range: -40° to + 85° Celcius.
  • Maximum pressure: 10 bar.
  • Viscosity: Max. 15 cSt (depending on the
    measurement range).
  • Process connection:   BSP, NPT or flexible
    hose fitting, see tables 2 and 3.
  • Materials: All wetted parts are manu-
    factured from PVDF.
  • Power supply: 5 - 12 VDC, 6 - 33 mA.
    8 – 24 VDC, 18 – 30 mA.
  • Pulse output: Open collector.
  • Max. load: 500 W
  • Frequency: 15 - 2400 Hz, see table 1.
  • Signal generation: Optoelectronic (infrared).
  • Signal cable: 1 meter protected cable,
    other lengths on request.
  • Optional: Filters 100 micron on sizes 1,2,3
Measurement range

Table 1:

Typ

Messbereich

K-Faktor < 5 cSt

Ausgang

(l/min)

(Impulse/l)

(Hz)

1*

0.1 - 2.0

36000

60 - 1200

2*

0.3 - 9.0

8000

40 - 1200

3*

0.5 - 15.0

3200

26.66 - 800

3*

0.5 - 15.0

1070

8.88 - 266.66

4

1.0 - 30.0

1200

20 - 600

5

2.0 - 75.0

450

18.75 - 562

6

4.0 - 120.0

225

15 - 450

 

 

BSP or NPT connection

Table 2 (Dimensions mm):

Type

A

D

d

L

1

9,5

1/4"

6,5

39

2

12,7

1/2"

13

47

3

12,7

1/2"

13

47

4

18,5

3/4"

17

63

5

24,5

1 1/4"

29

80

6

24,5

1 1/4"

29

80

  

Flexible hose fitting connection

Table 3:


Type


A


D


E


F


G


H


l

Tot.
L

1*

9,0

M12*1,5

8,7

1,5

6,5

6,9

39

96

2*

12,0

M20*2

16,0

1,8

12,0

9,0

43

112

3*

12,0

M20*2

16,0

1,8

12,0

12,0

43

116

4

16,0

M27*2

21,0

2,3

16,0

16,0

57

136

5

16,5

BSP 1" Pl

29,4

1,6

24,5

19,5

80

182

6

16,5

BSP 1" Pl

29,4

1,6

24,5

24,5

80

183